10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
These 10 free KY-MP questions are organized by exam domain, so you can see how each part of the Kentucky Master Plumber License Exam blueprint is tested. Reveal the answer and explanation under each question.
Domain 1: Written
Question 1
After a check valve is installed at a building's water meter, a recording gauge downstream shows a gradual rise from 55 to 105 psi during water-heater recovery with all fixtures closed. Upstream pressure stays at 55 psi, stored water remains near 125 degrees F, and opening a faucet promptly releases the elevated pressure. With the heater off, pressure remains steady. The pattern most strongly indicates:
Show answer & explanation
Correct answer: D - Thermal expansion trapped within a closed water system
Question 2
A fixture 30 feet above the service gauge requires at least 25 psi while operating. At the required design flow, the service gauge reads 58 psi; its no-flow reading is 76 psi. Pipe friction accounts for 9 psi and intervening devices for another 4 psi. Use 0.433 psi of pressure loss per foot of rise; no other losses apply. Which estimate correctly determines whether the fixture's operating-pressure requirement is met?
Show answer & explanation
Correct answer: B - About 32 psi; the operating-pressure requirement is met
Domain 2: Chart
Question 3
A construction company offers a Kentucky master plumber a fee to obtain permits. The company's crews would independently choose the plumbing design, materials, and installation methods; the master would have no authority over their work. Before the company can lawfully operate through that master's license, what essential change is needed?
Show answer & explanation
Correct answer: A - Place the plumbing work under the master's actual responsible charge
More KY-MP practice questions
Question 4
An industrial mixing system contains toxic treatment chemicals. Its pump can raise process pressure to 85 psi while the connected potable supply is at 60 psi. The makeup connection remains continuously pressurized. Which mechanical device provides the necessary protection against this cross-connection?
Show answer & explanation
Correct answer: B - Reduced-pressure-principle backflow preventer
Question 5
On a drainage riser drawing, upper branch U carries three water closets and two lavatories. Lower branch L joins the stack below U and carries two water closets and three lavatories. Every water closet flushes 1.28 gallons. Use 4 drainage fixture units per water closet and 1 per lavatory. Stack S below both connections serves no other fixtures and has a developed length of 110 feet. Kentucky's 3-inch stack row allows 36 fixture units over 225 feet; its 4-inch row allows 172 fixture units with no listed length limit. Applying the water-closet-count restriction as well as the table, the smallest permissible size for S is:
Show answer & explanation
Correct answer: C - 4 inches
Question 6
A final plumbing test record documents installed fixtures, water-filled traps, air pressure equivalent to a 1-inch water column maintained for 20 minutes, no leaks, and no forcing of trap seals. The house sewer was tested separately. An apprentice questions the record because the earlier rough-in air test used 5 psi. How should the master evaluate the recorded final test?
Show answer & explanation
Correct answer: A - Accept its pressure and duration as meeting the final-test requirements
Question 7
A commercial sink filler is supplied by a nominal 1-inch pipe, but its effective discharge opening measures 3/4 inch. The nearest inside edge of that opening is 1 inch from a vertical backsplash that extends above the spout. What minimum vertical air gap must separate the outlet from the sink's flood-level rim?
Show answer & explanation
Correct answer: C - 2 1/4 inches
Question 8
Before backfilling beneath a building, a master finds a coupling in a PEX water-distribution run that will be permanently buried under the slab. The coupling is approved for use with that tubing, and the assembly has passed its water-pressure test. Which revision resolves the Kentucky installation violation?
Show answer & explanation
Correct answer: D - Replace the affected run with continuous PEX without buried fittings
Question 9
A foreman's rough-in note reads: '3-inch water-closet branch; developed trap-to-vent distance 5 feet 4 inches; acceptable under the 6-foot table allowance.' Which rule invalidates that approval?
Show answer & explanation
Correct answer: A - The separate water-closet branch limit is 4 feet 6 inches
Question 10
A master plumber is reactivating a license after four years on properly maintained inactive status. No continuing education was completed during the earlier inactive years, but the plumber has now completed six approved, nonsafety plumbing-code hours within the past 12 months. What does Kentucky require regarding continuing education at reactivation?
Show answer & explanation
Correct answer: D - Submit proof of the six approved hours completed within the past 12 months
That's 10 of 1,030
The full bank has 1,020 more KY-MP questions with explanations.